PD.1550 in a 60L box.

  • needlefx
  • Topic Author
  • Offline
  • New Member
  • New Member
More
15 years 5 months ago #6031 by needlefx
PD.1550 in a 60L box. was created by needlefx
Hi.

I'm trying to find out if would work to fit a Precision-devices PD.1550 in a 60L reflex vented box. In spite of the recommended enclosure being 80-200L

My questions are:

Would the cone rip apart?

If doesn't.

What kind of reductions in power and quality of sound i'll suffer?

Should I increase the crossover point in order to protect the speaker ( makes any sense?? ) ?

If so

what is the recommended xover point?


Thanks in advance for any help.

Please Log in or Create an account to join the conversation.

More
15 years 5 months ago #6032 by nickyburnell
Replied by nickyburnell on topic PD.1550 in a 60L box.
What do you want the box to do?

Please Log in or Create an account to join the conversation.

  • needlefx
  • Topic Author
  • Offline
  • New Member
  • New Member
More
15 years 5 months ago #6035 by needlefx
Replied by needlefx on topic PD.1550 in a 60L box.
I'd like to get as much as I can from them ( not a lot eh!? ).

Basically use it from 40/45hz-110/150hz as loud as I can without damaging the speaker.

Please Log in or Create an account to join the conversation.

More
15 years 5 months ago #6036 by nickyburnell
Replied by nickyburnell on topic PD.1550 in a 60L box.
Tuning it to 60hz gives -3b and fairly flat there on up. 60l internel. Single round port 102mm dia 48.8mm deep.
Change the port lenth to 88.3mm length for -5db @ 50hz

Trying to tune lower gets crap.

The above is 60l INTERNAL volume in WinISD

Ripping the cone? This is LESS likley in a smaller box due to damping.

Please Log in or Create an account to join the conversation.

  • needlefx
  • Topic Author
  • Offline
  • New Member
  • New Member
More
15 years 5 months ago #6040 by needlefx
Replied by needlefx on topic PD.1550 in a 60L box.

What do you think about the Beyma 15G40 instead? Good contender?

Thanks for your time.

Please Log in or Create an account to join the conversation.

More
15 years 5 months ago #6041 by Tony Wilkes
Replied by Tony Wilkes on topic PD.1550 in a 60L box.
Beyma 15P1000 or 15P1200 the PD is not really suitable.

Tony

Please Log in or Create an account to join the conversation.